Military Housing Office Inspection Kits
Notice ID: MHO194
Amended paragraph #3 & #7 on 30 June 2026 (see attachments)
1. Binoculars; Quantity = 194
Make/Model: Fujinon 10x50, Steiner 10x50 Military Marine, or equivalent
Specifications for "Steinger Military Marine 10x50" (or equal) products:
- Magnification: 10x
- Objective Lens Diameter: No less than 50mm
- Field of View: No less than 327 ft at 1000 yds
- Focus: Auto Focus System
- Optics: Fully coated high contrast optics
- Close Focus: No more than 75 ft
- IP Distance: 56-74mm
- Diopter Range: +/- 5 pdt
- Luminosity: No less than 25
- Durability: Rubber Armoring (Rugged), Waterproof, Housing designed for minimum 8G impact
- Includes: Objective Covers, Carrying Case, High Contrast, Neck Strap
2. Borescopes; Quantity = 194
Make/Model: Teslong TD-500, Kentfaith Dual -Lens Articulating Borescope, or equivalent
Specifications for "Teslong TD-500" (or equal) products:
- Camera Pixels: 1.0 Megapixel minimum
- Probe: 2 Way Articulating Probe, 210 deg articulation, diameter no greater than 8.55 mm
- Field of View: 60 degrees minimum
- Display: 5 inch minimum, with a screen resolution of at least 854x480 pixels
- Probe Length: Between 4 to 8 feet
- Image Resolution: 1920x1080 pixel
- Durability: IP 67 waterproof
3. Combination IR and Probe Thermometers; Quantity = 194
Thermoworks IRT-2 with standard type T straight probe or equal.
Minimum IR Range -40 to 250 deg F
Minimum IR accuracy +/- 1.8 deg F from 32 deg to 149 deg F
Thermocoupler (probe) specifications
Minimum Range 32 deg F to 149 deg F minimum
Minimum Accuracy +/- 0.9 deg F from 32 deg F to 149 deg F
Must include a type T straight Penetration Probe, standard tip
4. Combustible Gas Meters / Combustible Gas Leak Detection; Quantity = 194
Make/Model: TPI 775, BPI Basics Kit, Gas Leak Detector CO Monitor, or equivalent
Specifications for "TPI 775 " (or equal) products:
Carbon Monoxide Detection:
- Resolution: 1ppm or lower
- Range: 0-2,000ppm or larger range
- Accuracy: +/- 5ppm or 5% of reading (whichever is greater) or better
Combustible Gas Leak Detection:
- Resolution: <50ppm
- Range: 0 – 50,000 ppm
- Accuracy: +/- 10%
- Detectable Gases: Must detect Natural Gas and Propane
- Alarms: Audible alarm for leaks, adjustable gas upper alarm threshold limit for alarm to permit gas leak isolation
5. GFCI Testers; Quantity = 194
Make/Model: Ideal 61-502 or equivalent
Specifications for "Ideal 61-502 120V AC Receptacle Tester" (or equal) product:
- Certification: UL 1436 and CSA C22.2 no 160 listed
- Detection Capabilities: Detects open ground, reverse polarity, open hot, open neutral, hot and ground reversed, and hot on neutral with hot open.
- Functionality: Push to Test function to test operation of GFCI receptacles.
6. Water Pressure Testers; Quantity = 194
Make/Model: Watts 3/4 Inch Plastic Water Pressure Test Guage, or equivalent
Specifications for "WATTS ¾ inch Plastic Water Pressure Test Gauge" (or equal)
- Connection: ¾ inch FIP connection
- Accuracy: ASME, type B
- Working Pressure: 0-140 psi
- Max Pressure: 200 psi
7. Thermal Imagers; Quantity = 194
Thermal imager minmum specifications:
- Thermal resolution: 160 x 120 pixels or greater
- Thermal sensitivity: < 150 mK or lower
- Field of View: 57 deg x 44 deg or higher
- Temperature range: 32 deg F to 170 deg F or greater
- Image modes: Thermal, Visual and mode that embosses visual details into thermal images
Digital camera minimum specifications
- 2 MP or greater
- 70deg x 55 deg minimum field of view
- 320 x 240 pixel minimal color display
Built in Moisture Detection both pinless and external pin probes (in lieu of this the vender can provide a separate moisture meter)
- Pinless depth to 0.75 inches
- Pin probes provided for pin operation
- Range 7% to 30% or greater with accuracy to +/- 1.5%
- Range 30% to 100% with reference only accuracy
Built in Air Temperature, Relative Humidity and Dew Point sensors (in lieu of this the vender can provide a separate meter to measure temperature, relative humidity and dew point)
- Temperature range: 32 deg F to 120 deg F or greater with minimum accuracy of +/- 1.1 deg F or better
- Relative Humidity range: 10%-90% or greater/ accuracy +/- 2.5% or better
- Dew Point -20 deg F to 120 Deg F or greater with accuracy of +/- 1.8 Deg F or better
Office