Military Housing Office Inspection Kits
Notice ID: MHO194

Amended paragraph #3 & #7 on 30 June 2026 (see attachments)

1. Binoculars;     Quantity = 194

Make/Model: Fujinon 10x50, Steiner 10x50 Military Marine, or equivalent

Specifications for "Steinger Military Marine 10x50" (or equal) products:

  • Magnification: 10x
  • Objective Lens Diameter: No less than 50mm
  • Field of View: No less than 327 ft at 1000 yds
  • Focus: Auto Focus System
  • Optics: Fully coated high contrast optics
  • Close Focus: No more than 75 ft
  • IP Distance: 56-74mm
  • Diopter Range: +/- 5 pdt
  • Luminosity: No less than 25
  • Durability: Rubber Armoring (Rugged), Waterproof, Housing designed for minimum 8G impact
  • Includes: Objective Covers, Carrying Case, High Contrast, Neck Strap

2. Borescopes;     Quantity = 194

Make/Model: Teslong TD-500, Kentfaith Dual -Lens Articulating Borescope, or equivalent

Specifications for "Teslong TD-500" (or equal) products:

  • Camera Pixels: 1.0 Megapixel minimum
  • Probe: 2 Way Articulating Probe, 210 deg articulation, diameter no greater than 8.55 mm
  • Field of View: 60 degrees minimum
  • Display: 5 inch minimum, with a screen resolution of at least 854x480 pixels
  • Probe Length: Between 4 to 8 feet
  • Image Resolution: 1920x1080 pixel
  • Durability: IP 67 waterproof

3. Combination IR and Probe Thermometers;     Quantity = 194

Thermoworks IRT-2  with standard type T straight probe or equal.

  Minimum IR Range -40 to 250 deg F 
  Minimum IR accuracy +/- 1.8 deg F from 32 deg to 149 deg F

Thermocoupler (probe) specifications
   Minimum Range 32 deg F to 149 deg F minimum
   Minimum Accuracy +/- 0.9 deg F from 32 deg F to 149 deg F

Must include a type T straight Penetration Probe, standard tip

4. Combustible Gas Meters / Combustible Gas Leak Detection;     Quantity = 194

Make/Model: TPI 775, BPI Basics Kit, Gas Leak Detector CO Monitor, or equivalent

Specifications for "TPI 775 " (or equal) products:

Carbon Monoxide Detection:

  • Resolution: 1ppm or lower
  • Range: 0-2,000ppm or larger range
  • Accuracy: +/- 5ppm or 5% of reading (whichever is greater) or better

 Combustible Gas Leak Detection:

  • Resolution: <50ppm
  • Range: 0 – 50,000 ppm
  • Accuracy: +/- 10%
  • Detectable Gases: Must detect Natural Gas and Propane
  • Alarms: Audible alarm for leaks, adjustable gas upper alarm threshold limit for alarm to permit gas leak isolation

5. GFCI Testers;    Quantity = 194

Make/Model: Ideal 61-502 or equivalent

Specifications for "Ideal 61-502 120V AC Receptacle Tester" (or equal) product:

  • Certification: UL 1436 and CSA C22.2 no 160 listed
  • Detection Capabilities: Detects open ground, reverse polarity, open hot, open neutral, hot and ground reversed, and hot on neutral with hot open.
  • Functionality: Push to Test function to test operation of GFCI receptacles.

6. Water Pressure Testers;     Quantity = 194

Make/Model: Watts 3/4 Inch Plastic Water Pressure Test Guage, or equivalent

Specifications for "WATTS ¾ inch Plastic Water Pressure Test Gauge" (or equal)

  • Connection: ¾ inch FIP connection
  • Accuracy: ASME, type B
  • Working Pressure: 0-140 psi
  • Max Pressure: 200 psi

7. Thermal Imagers;     Quantity = 194

Thermal imager minmum specifications:

  • Thermal resolution:  160 x 120 pixels or greater
  • Thermal sensitivity: < 150 mK or lower
  • Field of View:  57 deg x 44 deg or higher
  • Temperature range:  32 deg F to 170 deg F or greater
  • Image modes: Thermal, Visual and mode that embosses visual details into thermal images

Digital camera minimum specifications

  • 2 MP or greater
  • 70deg x 55 deg minimum field of view
  • 320 x 240 pixel minimal color display

Built in Moisture Detection both pinless and external pin probes (in lieu of this the vender can provide a separate moisture meter)

  • Pinless depth to 0.75 inches
  • Pin probes provided for pin operation
  • Range 7% to 30% or greater with accuracy to +/- 1.5%
  • Range 30% to 100% with reference only accuracy

Built in Air Temperature, Relative Humidity and Dew Point sensors (in lieu of this the vender can provide a separate meter to measure temperature, relative humidity and dew point)

  • Temperature range:  32 deg F to 120 deg F or greater with minimum accuracy of +/- 1.1 deg F or better
  • Relative Humidity range: 10%-90% or greater/ accuracy +/- 2.5% or better
  • Dew Point -20 deg F to 120 Deg F or greater  with accuracy of +/- 1.8 Deg F or better

Department/Ind.Agency DEPT OF DEFENSE
Office
AIR FORCE MATERIEL COMMAND
Contract Opportunities
Notice Type
Solicitation
Updated Date
2026-06-30
Published Date
2026-06-30
Logo

Don't have an account? Sign Up

Forgot password?